Author(s)
P. Cornic; M. Hebey; J. Le Bris; B. Leclaire; F. Champagnat; A. Cheminet
Institution(s)
ONERA; CEA
Algorithm short name
ITE-PTV
Algorithm full name
Iterative Tomographic Enhanced PTV
Publication date
Thu Jul 31 09:50:09 2025
Submitter name
Philippe Cornic
ppp
0.12
#TP t0
150430
#FP t0
64
#FN t0
1794
Precision t0
1
Recall t0
0.988
#TP t1
150439
#FP t1
55
#FN t1
1785
Precision t1
1
Recall t1
0.988
#TP vectors
150324
#FP vectors
170
#FN vectors
1900
Vector Precision
0.999
Vector Recall
0.988
Pos. rms error t0
0.088
Pos. rms error t1
0.088
Disp. rms error
0.113
X pos. rms error t0
0.0337
X pos. rms error t1
0.0337
Y pos. rms error t0
0.0284
Y pos. rms error t1
0.0283
Z pos. rms error t0
0.0762
Z pos. rms error t1
0.0762
Mie
Off