Author(s)
P. Cornic; M. Hebey; J. Le Bris; B. Leclaire; F. Champagnat; A. Cheminet
Institution(s)
ONERA; CEA
Algorithm short name
ITE-PTV
Algorithm full name
Iterative Tomographic Enhanced PTV
Publication date
Thu Jul 31 09:50:09 2025
Submitter name
Philippe Cornic
ppp
0.025
#TP t0
32117
#FP t0
0
#FN t0
44
Precision t0
1
Recall t0
0.999
#TP t1
32117
#FP t1
0
#FN t1
44
Precision t1
1
Recall t1
0.999
#TP vectors
32113
#FP vectors
4
#FN vectors
48
Vector Precision
1
Vector Recall
0.999
Pos. rms error t0
0.0511
Pos. rms error t1
0.0511
Disp. rms error
0.0669
X pos. rms error t0
0.0233
X pos. rms error t1
0.0231
Y pos. rms error t0
0.0163
Y pos. rms error t1
0.0166
Z pos. rms error t0
0.0424
Z pos. rms error t1
0.0425
Mie
Off